Move to the body of this page
Transmitters

High response type transmitter CSA-522B

Features

・ High response direct amplifier
・ For measuring load, pressure, torque anddisplacement.
・ Auto zero function as an option

Specification

Specification name Specification contents
Bridge power supply 10 VDC±0.3VDC within 120 mA
(Changeable to 2.5 VDC or 5 VDC.)
Input range 0.35 mV/V ~ 3.5 mV/V
Sensitivity ±10 V (Non-isolation)
Load resistance 500 ohm or more
Sensitivity adjustable range L: 1 000 times, M: 2 000 times, H: 3 000 times
Adjustable from 1/1 to 1/4 on each setting
Zero adjustment range ±0.6 mV/V
Non-linearity
(Display and voltage output)
0.005 %F.S.
Temperature efficient Zero point ±0.2 μV/℃ (Inputconversion)
Sensitivity ±0.005 %F.S./℃
Frequency response range 1 Hz or 30 Hz (-12dB/oct bessel type),
25 kHz (-3 dB)
Current output DC4 mA ~ 20 mA
(Non-isolation,at the voltage output DC0 V ~ 10 V)
Load resistance 510 ohm or less, Non-linearity 0.05%F.S.
Operating temp. / humidity range Temperature -10 ℃~ 50 ℃
Humidity 85 %RHor less(Non condensing)
Power supply 100 VAC (Permissiblevariable range: 90 VAC ~ 110 VAC) 50/60Hz
Power consumption Approx. 15 VA
Outline dimensions (WxHxD) 49.5 mm x 138 mm x 173.6mm (Excludes protruding parts)
Weight Approx. 1.1 kg
Options Auto zero, Power supply voltage

Download

Instruction Manual

Specification

Options

  • Auto zero
  • Power supply voltage
Page Top