DC Fans Common Specifications
Standard
Vibration Test
Conforms to JIS C 60068-2-6
Peak-to-Peak value of a vibration: 1.5mm
Frequency 10 to 55 Hz, 1 hour each in the X, Y and Z directions.
Please contact us for Fan motors for refrigerators.
Shock Test
Conforms to JIS C 60068-2-27
Acceleration 981 m/s2*
Application time 6 ms once each in the X, Y and Z directions
Note: Acceleration rate 500 m/s2, Application time 11 ms once each in the X, Y and Z directions.
Application | Model | |||
---|---|---|---|---|
General | 02510SS | 03010SS | 03510SS | - |
04010SS | 04010SA | 2004KL | 2404KL | |
Blower Fan | 04520GA | 05020GA | - | - |
Please contact us for Fan motors for refrigerators. |
Burnout Protection
The fan motor will not burnout when restricted for 72 hours at the rated voltage.
Polarity Protection
The reverse connection at the rated voltage will not cause damage.
Insulation Class
E class (UL: CLASS A)
Protection System
Motor burnout is prevented by the current cut-off automatic restoration function.
Standard values
Max. Air quantity, Max static pressure, Rotations, Drive noise (Intake side), Mass, Rating current, Rating input
Notes
- Additional performance requirements may be determined between manufacturer and customer, based on the customer's request.
- Fans may be installed in a horizontal, vertical, or angled position.
DC Fan Motor Recommended Connectors
Connector Pitch | Housing | Contact | Manufacturer |
---|---|---|---|
2mm | PHR-* A2001H02-*P 173977-* |
SPH-002T-P0.5S A2001T0P-2 (Touch Type) |
JST JWT Tyco Electronics |
2.5mm | EHR-* A2502H02-*P XHP-* A2501H02-*P |
SEH-001T-P0.6 A2502T0P-2 SXH-001T-P0.6 A2501T0P-2 |
JST JWT JST JWT |
Note: *mark means the number of pole. For example "2" means 2 poles and "3" means 3 poles.