Outline
MM414x series are Li-ion battery protection IC and detect charge current / discharge current with high precision by current sensing resistor (Rsns). MM414x have two step discharge overcurrent detection. And system is protected appropriately in the next 2 state, Normal discharge mode and large current discharge mode.
Product Series
For one-cell
Features
1) Range and accuracy of detection voltage
Overcharge detection voltage 3.8V to 4.8V, 5mV steps Accuracy±15mV
Overdischarge detection voltage 2.0V to 3.0V, 50mV steps Accuracy±35mV
Discharging overcurrent detection voltage 1 +3mV to +50mV, 0.1mV steps Accuracy±1.00mV(MM4140 Series)
Accuracy±0.75mV(MM4141 Series)
Accuracy±0.50mV(MM4142 Series)
Discharging overcurrent detection voltage 2 +6mV to +100mV, 0.5mV steps Accuracy±2.00mV(MM4140/MM4141 Series)
Accuracy±1.50mV(MM4142 Series)
Charging overcurrent detection voltage -50mV to -3mV, 0.1mV steps Accuracy±1.00mV(MM4140 Series)
Accuracy±0.75mV(MM4141 Series)
Accuracy±0.50mV(MM4142 Series)
Short detection voltage +10mV to +150mV, 1mV steps Accuracy±2.5mV
0V Battery Charging Inhibition Voltage 1.2V~2.0V, 0.1V steps Accuracy±0.2V(1.2V)
Accuracy±0.1V(1.3V~2.0V)
2) Low current consumption
Normal mode Typ. 2.5μA, Max. 4.0μA
Stand-by mode(Overdischarge Latch ""ENABLE"") Max. 0.1μA
Stand-by mode(Overdischarge Latch ""DISABLE"") Max. 0.5μA
Specifications
Product name |
Package | 0V battery charge function |
Overcharge release function | Overdischarge release function | Discharging overcurrent release function | Overcharge detection voltage [V] |
Overcharge release voltage [V] |
Overdischarge detection voltage [V] |
Overdischarge release voltage [V] |
Discharging overcurrent detection voltage1 [V] |
Discharging overcurrent detection voltage2 [V] |
Charging overcurrent detection voltage [V] |
Short detection voltage [V] |
Overcharge detection delay time [s] |
Overcharge release delay time [ms] |
Overdischarge detection delay time [ms] |
Overdischarge release delay time [ms] |
Discharging overcurrent detection delay time 1 [ms] |
Discharging overcurrent detection delay time 2 [ms] |
Discharging overcurrent release delay time [ms] |
Charging overcurrent detection delay time [ms] |
Charging overcurrent release delay time [ms] |
Short detection delay time [ms] |
---|