Blowers rotate fans to cool the inside of office automation (OA) equipment by directing heat outside. These motors are used for such applications as the OA equipment in which a stronger airflow is required for cooling than the normal type of fan motors.
General Specifications
Motor Protection:Auto Restart / Polarity Protection (except N Class)
Insulation Resistance:10M ohm or over with a DC500V Megger
Dielectric Withstand Voltage:AC700V 1s
Allowable Ambient Temperature Range :
L、M Class:-10deg.C - +70deg.C (Operating)
N Class: -10deg.C - +60deg.C (Operating)
-40deg.C - +70deg.C (Storage)
non-condensing environment
-
-
Click the arrow icon in the table below to switch from ascending to descending order.
scroll
Model
Product No
Nominal Voltage
[V]Operating Voltage
lower limit
[V]Operating Voltage
upper limit
[V]Current
[A]Input Power
[W]Speed
[min-1]Max. Air Flow
[m3/min]Max. Air Flow
[CFM]Max. Static Pressure
[Pa]Max. Static Pressure
[In H2O]Noise
[dB]Mass
[g]06023GA-12L-AA-00 00 12 6.0 13.8 0.11 1.32 3500 0.17 6.00 110 0.44 30.0 60 06023GA-12M-AA-00 00 12 6.0 13.8 0.23 2.76 4500 0.22 7.70 200 0.80 37.0 60 06023GA-12N-AA-00 00 12 6.0 13.2 0.26 3.12 5000 0.24 8.40 230 0.92 41.0 60 Rotation: Clockwise as seen from the label side
*1: Average Values in Free AirOutline
Characteristic Curves
-
25deg.C 60,000 Hours *Failure Rate 10% (L10 Life)
-
Casing Lower:Plastic (Black) UL94V-0
Casing Upper:Steel
Impeller:Plastic (Black) UL94V-0
Bearing:Ball Bearing
Lead Wire:UL1061 AWG26 +: Red, -: Black -
Associated Data
CAD
Download
Industry
Contact Us
Please click the inquiry type below according to your question. Each product / sales representative will respond to you.