1. Fan Motors
  2. DC blower fan motors

06023GS(Three Phase)

Blowers rotate fans to cool the inside of office automation (OA) equipment by directing heat outside. These motors are used for such applications as the OA equipment in which a stronger airflow is required for cooling than the normal type of fan motors.

General Specifications

Motor Protection:Auto Restart / Polarity Protection
Insulation Resistance:10M ohm or over with a DC500V Megger
Dielectric Withstand Voltage:AC700V 1s
Allowable Ambient Temperature Range :
-10deg.C - +60deg.C (Operating)
-40deg.C - +70deg.C (Storage)
non-condensing environment

  • Click the arrow icon in the table below to switch from ascending to descending order.

    scroll

    Model

    Product No

    Nominal Voltage
    [V]

    Operating Voltage
    lower limit
    [V]

    Operating Voltage
    upper limit
    [V]

    Current
    [A]

    Input Power
    [W]

    Speed
    [min-1]

    Max. Air Flow
    [m3/min]

    Max. Air Flow
    [CFM]

    Max. Static Pressure
    [Pa]

    Max. Static Pressure
    [In H2O]

    Noise
    [dB]

    Mass
    [g]

    06023GS-12Q-AE-00 00 12 7.0 12.6 0.32 3.84 6000 0.34 11.90 294 1.17 43.5 52

    Rotation: Clockwise as seen from the label side
    *1: Average Values in Free Air

    Outline

    Characteristic Curves

  • 60deg.C 20,000 Hours *Failure Rate 10% (L10 Life)

  • Casing:Plastic (Black) UL94V-0
    Impeller:Plastic (Black) UL94V-0
    Bearing:Sleeve Bearing
    Lead Wire:UL1061 AWG26 +: Red, -: Black