Blowers rotate fans to cool the inside of office automation (OA) equipment by directing heat outside. These motors are used for such applications as the OA equipment in which a stronger airflow is required for cooling than the normal type of fan motors.

General Specifications

Motor Protection:Auto Restart / Polarity Protection
Insulation Resistance:10M ohm or over with a DC500V Megger
Dielectric Withstand Voltage:AC700V 1s
Allowable Ambient Temperature Range :
-10deg.C - +70deg.C (Operating)
-40deg.C - +70deg.C (Storage)
non-condensing environment

  • Click the arrow icon in the table below to switch from ascending to descending order.

    scroll

    Model

    Product No

    Nominal Voltage
    [V]

    Operating Voltage
    lower limit
    [V]

    Operating Voltage
    upper limit
    [V]

    Current
    [A]

    Input Power
    [W]

    Speed
    [min-1]

    Max. Air Flow
    [m3/min]

    Max. Air Flow
    [CFM]

    Max. Static Pressure
    [Pa]

    Max. Static Pressure
    [In H2O]

    Noise
    [dB]

    Mass
    [g]

    05125GS-12N-AAD-00 00 12 6.0 13.8 0.20 2.40 5700 0.20 7.10 170 0.68 39.0 35
    05125GS-24N-AAD-00 00 24 10.0 27.6 0.15 3.60 5700 0.20 7.10 170 0.68 39.0 35

    Rotation: Clockwise as seen from the label side
    Airflow Outlet: Label side
    *1: Average Values in Free Air

    Outline

    Characteristic Curves

  • 40deg.C 40,000 Hours *Failure Rate 10% (L10 Life)

  • Casing Lower:Plastic (Black) UL94V-0
    Impeller:Plastic (Black) UL94V-0
    Bearing:Sleeve Bearing
    Lead Wire:UL1061 AWG26 +: Red, -: Black

  • Associated Data

    CAD

Contact Us