Features
Load cell for truck scale with stainless steel construction.
Approved OIML R60 Class C6.
Specification
Specification name | Specification contents |
---|---|
OIML accuracy class | OIML R60 C6 |
Maximum scale interval | 6,000 |
Rated capacity | 10t~30t |
Model No. (Capacity) | 1kg~3kg |
Safe overload | 150 %R.C. |
Ultimate overload | 200 %R.C. |
Rated output | 2 mV/V±0.002 mV/V |
Non-linearity | 0.012 %R.O. |
Hysteresis | 0.012 %R.O. |
Repeatability | 0.010 %R.O. |
Creep | 0.008 %R.O./30 min |
Zero return | 0.008 %R.O./30 min |
Excitation, recommended | 12 VDC or less |
Excitation, maximum | 20 VDC |
Zero balance | ±0.02 mV/V |
Input resistance | 770 Ω~830 Ω |
Output resistance | 695 Ω~705 Ω |
Insulation resistance | 5,000 MΩ or more (DC50 V)(between bridge and main body) |
Temp. range, compensated | -10 ℃~40 ℃ |
Temp. range, safe | -20 ℃~70 ℃ |
Temp. effect on zero | 0.014 %R.O./10 ℃ |
Temp. effect on output | 0.010 %LOAD/10 ℃ |
Class of protection | IP68 or equivalent |
Material of element | Alloy steel |
Material of Cover | Stainless steel (lost wax) |
Durability | 1,000,000 times with rated load applied. |
Horizontal maximum movable distance | 0 mm,However, please hit the stopper of the track scale within 5 mm.Recommendation 2 mm ~ 3 mm |
Accessories | Guide ring, Inspection data sheet |
Table of P/N
Parts No. | Rated capacity [t] |
Natural frequency [Hz] |
Rated displacement [mm] |
Weight(Approx. ) [kg] |
Cable | CAD files[DXF] | Specification sheet | Instruction Manual |
---|
Options
- <Mounting attachment>
- AIC series AIC2