It is the latest design for servers and communication devices that realize high rotation, high air volume, and high static pressure.
General Specifications
Motor Protection:Auto Restart / Polarity Protection
Insulation Resistance:10M ohm or over with a DC500V Megger
Dielectric Withstand Voltage:AC700V 1s
Allowable Ambient Temperature Range :-10deg.C - +60deg.C (Operating)
-30deg.C - +60deg.C (Storage)
non-condensing environment
-
-
Click the arrow icon in the table below to switch from ascending to descending order.
scroll
Model
Product No
Nominal Voltage
[V]Operating Voltage
lower limit
[V]Operating Voltage
upper limit
[V]Current
[A]Input Power
[W]Speed Inlet
[min-1]Speed Outlet
[min-1]Max. Air Flow
[m3/min]Max. Air Flow
[CFM]Max. Static Pressure
[Pa]Max. Static Pressure
[In H2O]Noise
[dB]Mass
[g]080A0EA-12S-E6-00 00 12 10.8 12.6 7.75 93.00 15200 12600 4.75 167.70 1850.0 7.41 78.5 530.0 Rotation:
Clockwise as seen from the Outlet impeller side.
Counter Clockwise as seen from the Outlet impeller side.
Airflow Outlet: Outlet Impeller Side
*1: Average Values in Free AirOutline
Characteristic Curves
-
40deg.C 70,000 Hours, Target Value *Failure Rate 10% (L10 Life)
60deg.C 40,000 Hours, Target Value *Failure Rate 10% (L10 Life) -
Casing:Plastic (Black) UL94V-0
Impeller:Plastic (Black) UL94V-0
Bearing:Ball
Bearing Lead Wire:UL3385 or UL10368 AWG20 +: Red, -: Black,
+: Red/White, -:Black/White -
Associated Data
Engineering Information
Download
Industry
Contact Us
Please click the inquiry type below according to your question. Each product / sales representative will respond to you.