Features
Suitable for high explosion risk envitonment such as with flammable liquid or gas.
Specification
Specification name | Specification contents |
---|---|
Rated capacity | 1.961 kN {200 kgf}~196.1 kN {20 tf} |
Safe overload | 150 %R.C. |
Ultimate overload | 200 %R.C. |
Rated output | 2.8 mV/V±0.002 8 mV/V(CCP1-2T~20T-Z:3 mV/V±0.003 mV/V) |
Non-linearity | 0.05 %R.O. |
Hysteresis | 0.02 %R.O. |
Repeatability | 0.02 %R.O. |
Excitation, recommended | 12 V or less |
Excitation, maximum | 20 V |
Zero balance | ±0.028 mV/V (CCP1-2T~20T-Z:0.03 mV/V) |
Input resistance | 350 Ω±3.5 Ω |
Output resistance | 350 Ω±5 Ω |
Insulation resistance | 2,000 MΩ or more (DC50 V)(between bridge and main body) |
Temp. range, compensated | -10 ℃~70 ℃ |
Temp. range, safe | -20 ℃~100 ℃ |
Temp. effect on zero | 0.03 %R.O./10 ℃ |
Temp. effect on output | 0.03 %LOAD/10 ℃ |
Class of protection | IP64 or equivalent |
Material of element | Alloy steel |
Paint | Painted with epoxy resin.(Munsell 6GY3.5/2 half-polished resemblance color) |
Durability | 1,000,000 times with rated load applied. |
Terminal box | Fixed with solderless terminal screws on the terminal plate |
Cable retracting method | Explosion-proof packing type |
Piping method | Thick steel conduit tube |
Table of P/N
Parts No. | Rated capacity [kN] |
Rated capacity [kgf] |
Rated capacity [tf] |
Natural frequency [Hz] |
Rated displacement [mm] |
Weight(Approx. ) [kg] |
Cable | 3D CAD files [STEP] | CAD files[DXF] | Specification sheet | Instruction Manual |
---|
Options
- <Expansion plate>
- EP series EP1
- <Bearing plate>
- BP/MP series BPMP1
- <Mounting plate>
- BP/MP series BPMP1
- <Mounting attachment with slide-stop mechanism>
- Flexibel lock method mounting attachment FCA-CCP1-* series