Both our tank scales and platform scales adopt intrinsically safe explosion-proof systems.

Features

・Serial communication means there is no display error relative to the indicator
・Selectable between board mounting types and wall/tabletop mounting types
・Up to 8 indicator units can be connected

  • scroll

    Specification name

    Specification contents

    Display LC display, with backlight、7 digits and decimal point, character height 18mm
    Display unit g , kg , t or lb
    Power supply 100~240V AC
    Power supply tolerance -15%~10%
    Maximum allowable power supply voltage 85~264V AC
    Frequency 47~440Hz
    Power consumption <5VA
    Operating temperature range -10℃~60℃
    Storage temperature range -20℃~70℃
    Interface RS232/RS485
  • Click the arrow icon in the table below to switch from ascending to descending order.

    scroll

    Parts No.

    Connector

    Housing

    Housing materials

    Class of protection

    Weight
    [kg]

    Gross Weight
    [kg]

    Specification sheet

    PR5110/00 2 x D-SUB 9pin ( male ) Panel housings Aluminum IP30 (Panel front IP65) 1 1.5 382PR5110.pdf
    PR5110/10 Cable ground/internal terminal block Tabletop housing Stainless steel / Electrolytic polishing IP65 1.4 2.3 382PR5110.pdf

Custom

  • Custom products are intended for mass production. Please consult us for small-lot orders.