Features
■Compact load cell with φ7mm×height 5mm (20 kgf / 50 kgf)~φ16mm×height 16mm(3tf).
■Achieve the small size, high accuracy and the low price by in-house strain gage technology.
■Excellent in noise-proof by 4-gage method, and do not receive the temperature effect easily even if the sensor is built into the metal mold with high temperature.
■A free metal mold design that doesn’t receive the restriction of the ejector pin diameter can be designed because of the method set up in the ejector pin bottom used.
Specification
| Specification name | Specification contents |
|---|---|
| Rated capacity | 196.1 N {20 kgf} ~ 29.42 kN {3 tf} |
| Safe overload | 150 %R.C. |
| Ultimate overload | 200 %R.C. |
| Rated output | 0.6 mV/V±0.1 mV/V |
| Non-linearity | 1 %R.O. (LSMS-500K-S06: 1.5 %R.O.) |
| Hysteresis | 1 %R.O. |
| Repeatability | 1 %R.O. |
| Recomended excitation | 5 VDC |
| Maximum excitation | LSMS-20K~100K-S06:12 V、LSMS-200K~3T-S06:8 V |
| Zero balance | ±0.1 mV/V |
| Input terminal resistance | LSMS-20K~100K-S06: 355 Ω±5 Ω, LSMS-200K/-500K-S06: 355 Ω±20 Ω, LSMS-1T-S06: 358 Ω±20 Ω, LSMS-3T-S06: 350 Ω±20 Ω, |
| Output terminal resistance | LSMS-20K~100K-S06: 355 Ω±5 Ω, LSMS-200K/-500K-S06: 355 Ω±20 Ω, LSMS-1T-S06: 358 Ω±20 Ω, LSMS-3T-S06: 350 Ω±20 Ω, |
| Insulation resistance | 1 000 MΩ or more (at DC50 V) (between bridge and main body) |
| Compensated temperature range | -10℃ ~ 150℃ |
| Safe temperature range | -20℃ ~ 150℃ |
| Temp. effect on zero balance | 1.0 %R.O./10℃ |
| Temp. effect on output | 1.0 %LOAD/10℃ |
| Cable | LSMS-20K~100K-S06: φ1.0, 4-cores 1.2 m shielded cable with connector at cable end. LSMS-200K~500K-S06: φ1.0, 4-cores 1.5 m shielded cable with connector at cable end. LSMS-1T-S06: φ1.8, 4-cores 2 m shielded cable with connector at cable end. LSMS-3T-S06: φ3.2, 4-cores 2 m shielded cable with connector at cable end. |
| Minimum bending radius of cable | LSMS-20K~500K-S06: 5 mm, LSMS-1T-S06: 10 mm, LSMS-3T-S06: 16 mm |
| Class of protection | IP64 |
| Material | Stainless steel HRC42 or more |
| Fatigue life | 1 000 000 times at rated load |
Table of P/N
| Parts No. | Rated capacity [N] |
Rated capacity [kN] |
Rated capacity [kgf] |
Rated capacity [tf] |
Natural frequency (for reference) [Hz] |
Rated displacement (for reference) [mm] |
External size (Diameter) [mm] |
External size (Height) [mm] |
Weight(Approx.) [g] |
2D CAD | 3D CAD |
|---|
Download
Specification sheet
CAD files[DXF]
Latest News
- 2025.01.22 Infomation INTEGRATED MOLD SENSING SYSTEM page has been published.