Move to the body of this page
Compression type for industrial weighing systems

Accurate canister type load cell CCP1(A)-※ series

Features

Ideal for the weighing system of hopper & tank scales, etc.

Specification

Specification name Specification contents
Rated capacity 490.3 N {50 kgf}~196.1 kN{20 tf}
Safe overload 150 %R.C. (CCP1-50K~100K:500 %R.C.)
Ultimate overload 200 %R.C. (CCP1-50K~100K:500 %R.C.)
Rated output 3 mV/V±0.003 mV/V
Non-linearity 0.05 %R.O.
Hysteresis 0.02 %R.O.(CCP1-50K~100K:0.05 %R.O.)
Repeatability 0.02 %R.O..(CCP1-50K~100K:0.05 %R.O.)
Excitation, recommended 12 V or less
Excitation, maximum 20 V
Zero balance ±0.03 mV/V
Input resistance 350 Ω±3.5 Ω
Output resistance 350 Ω±5 Ω
Insulation resistance 5,000 MΩ or more (DC50 V)(between bridge and main body)
Temp. range, compensated -10 ℃~70 ℃
Temp. range, safe -20 ℃~100 ℃
Temp. effect on zero 0.03 %R.O./10 ℃
Temp. effect on output 0.03 %LOAD/10 ℃
Class of protection IP64 or equivalent
Material of element Alloy steel
Paint Painted by epoxy resin(Munsell 6GY3.5/2 half polished resemblance color)
Durability 1,000,000 times with rated load applied.

Table of P/N

Parts No. Rated capacity
[N]
Rated capacity
[kN]
Rated capacity
[kgf]
Rated capacity
[tf]
Natural frequency
[Hz]
Rated displacement
[mm]
Weight(Approx. )
[kg]