Overview
The <MM3684 series> features built-in secondary protection function compliant with international standards for electronic tools, which contributes to improved safety during use.
The <MM3684 series> features the additional functions of temperature protection and multi-stage overcurrent protection. These help to achieve a low consumption current and better space efficiency that could not be achieved with existing circuit layouts, and also helps to improve safety of lithium ion batteries.
Features
- Built-in overcharge, over-discharge and overcurrent protection functions.
- 3-stage discharge overcurrent protection
- Detection of 2 values of high and low temperatures with an external NTC to protect battery packs
- Built-in secondary protection function to drive external FET for FUSE
- Intermittent operation with temperature protection for a low consumption current
- Over-discharge detection voltage switch function (2 values can be set)
Main specifications
Overcharge detection voltage | 1 : 3.6 to 4.5V (5mV steps) accuracy ±25mV |
2 : 3.6 to 4.5V (5mV steps) accuracy ±25mV | |
Over-discharge detection voltage | 1 : 2.0 to 3.0V (50mV steps) accuracy ±80mV |
2 : 2.0 to 3.0V (50mV steps) accuracy ±80mV | |
Discharge overcurrent detection voltage |
1 : 30 to 300mV (5mV steps) accuracy ±15% |
2 : 2x/4x discharge overcurrent 1 accuracy ±20% | |
Short circuit detection voltage | 4x/8x discharge overcurrent 1 accuracy ±100mV |
Charge overcurrent detection voltage | -300 to -20mV (5mV steps) accuracy ±10mV |
Temperature protection detection temperature |
-30℃ to 80℃ (5℃ steps, 2 values can be set) |
REG terminal output voltage | 1.5 to 3.0V (50mV steps) accuracy ±25mV |
Package | VSOP-24A |
Dimensions | 7.9×7.6×1.25 (W×D×H) (Unit : mm) |